High Light: | high temperature refrigerated dryer,high temperature air dryer,refrigerated air |
---|
freeze dryer
You need dry compressed air
Usually the compressed air entering the air network contains 100% water vapor. These vapors condense as the air cools, which can not only damage your compressed air system but also cause damage to your end product.
If a dryer is not installed, 90L of water will enter your compressed air system every day. HJL compressed air dryer can completely eliminate the moisture in compressed air. Dry compressed air ensures smooth operation of the compressed air system and production process. HJL series refrigerated dryers and adsorption dryers provide you with dry compressed air at different dew point temperatures.
1. Pre-cooling/heat exchanger
2. Evaporator
3. Soda water separator
4. Air condenser
5. Water condenser
6. Refrigerant compressor
7. Gas-liquid separator
8. High and low voltage switches
9. Drying filter 10. Expansion valve (capillary tube) 11. Hot gas bypass valve 12. Water volume regulating valve 13. Automatic drain valve 14. High pressure switch
refrigerated dryer (water-cooled type) Technical parameters | |||||||
Model | Air treatment(m³/min) | Compressor power (HP) | Power supply(V/50Hz) | Cooling water volume(m²/h) | Air pipe diameter | Dimensions(length x width x height mm) | Weight(Kg) |
BL0120W | 14 | 3 | 380 | 2.8 | DN65(G2½") | 700X1000X1000 | 160 |
BL0150W | 16 | 4 | 380 | 3 | DN65(G2½") | 800X1000X1000 | 165 |
BL0200W | 22.8 | 5 | 380 | 3.5 | DN80(F3) | 700X1450X1160 | 250 |
BL0250W | 28.5 | 6 | 380 | 4 | DN80(F3) | 700X1450X1160 | 300 |
BL0300W | 35 | 8 | 380 | 5 | DN80(F3) | 1800X1000X1360 | 400 |
BL0400W | 45 | 10 | 380 | 7 | DN100(F4) | 2000X1000X1360 | 500 |
BL0500W | 55 | 12.5 | 380 | 9 | DN100(F4) | 2200X1100X1480 | 600 |
BL0600W | 65 | 15 | 380 | 10 | DN125(F5) | 2200X1100X1480 | 700 |
BL0800W | 85 | 20 | 380 | 12 | DN150(F6) | 2300X1300X1880 | 900 |
BL1000W | 105 | 25 | 380 | 14 | DN150(F6) | 2400X1300X2100 | 1100 |
BL1200W | 120 | 30 | 380 | 16 | DN200(F8) | 2600X1800X2500 | 1500 |
BL1600W | 160 | 40 | 380 | 18 | DN200(F8) | 2800X2000X2600 | 1650 |
BL2000W | 200 | 50 | 380 | 24 | DN250(F10) | 3400X2100X2700 | 2000 |
BL2500W | 250 | 60 | 380 | 24 | DN250(F10) | 3800X2100X2800 | 2600 |
BL3000W | 300 | 70 | 380 | 35 | DN300(F12) | 4000X2100X2900 | 3500 |
BL3600W | 360 | 80 | 380 | 40 | DN300(F12) | 4200X2100X3000 | 4500 |
Standard working conditions | ||||
air inlet temperature | ambient temperature | work pressure | pressure dew point | refrigerant |
38℃ | 35℃ | 0.7MPa | 2-10℃ | R-22 |
Working range | ||
work pressure | ambient temperature | Maximum intake air temperature |
0.6~1.3MPa | 5~45℃ | <80℃ |