首页 >> NEWS >> IndustryNews>>Solutions to common faults of quality turnkey nitrogen generator system with high quality high req

Solutions to common faults of quality turnkey nitrogen generator system with high quality high req

  • Categories:IndustryNews
  • Author:超级管理员
  • Origin:
  • Time of issue:2022-11-07 12:42:45
  • Views:0

(Summary description)Solutions to common faults of quality turnkey nitrogen generator system with high quality high req1. During the operation of quality turnkey nitrogen generator system with high quality high req, the number displayed on the meter head is large, and the pressure cannot reach the set value, which is ca

Solutions to common faults of quality turnkey nitrogen generator system with high quality high req

(Summary description)Malaysia Psa Nitrogen Generator and Nitrogen Plant for Industry,Psa Nitrogen Generator and Nitrogen Making Machine manufacturers

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-11-07 12:42:45
  • Views:0
Information

Solutions to common faults of quality turnkey nitrogen generator system with high quality high req
1. During the operation of quality turnkey nitrogen generator system with high quality high req, the number displayed on the meter head is large, and the pressure cannot reach the set value, which is caused by the leakage device. Carry out a comprehensive leak detection on the gas circuit, especially the drying room and the battery.
2. Check whether the battery is leaking and damaged
(1)Open the side panel of the instrument, observe the black rubber pad between the battery panels to see if there is any protruding deformation and water seepage, if so, replace the battery;
(2)Turn off the power after the nitrogen input pressure is 5KG, the battery water circuit should be static, if there are blisters continuously emerging, the battery is broken;

HONGJINLI
3. There is a noise in the operation of quality turnkey nitrogen generator system with high quality high req, which is usually caused by the sound of the solenoid valve: use a 14 wrench to properly adjust the tightness of the nut on the solenoid valve, not too tight; if not, disassemble the solenoid valve to clean the interior (the main noise is It is because the solenoid valve is dirty with impurities), if it does not work after cleaning, it must be replaced with a new one.
4. Gas output when power on
When the pressure of quality turnkey nitrogen generator system with high quality high req just starts up, you need to press the red delay switch on the front, and then the output pressure is released, and it can be used after waiting for 10 minutes.


Keyword:

Scan the QR code to read on your phone

Related News

Solutions

Solutions to common faults of quality turnkey nitrogen generator system with high quality high req

Malaysia Psa Nitrogen Generator and Nitrogen Plant for Industry,Psa Nitrogen Generator and Nitrogen Making Machine manufacturers
2022-11-07
Solutions

Solutions to common faults of quality turnkey nitrogen generator system with high quality high req

Malaysia Psa Nitrogen Generator and Nitrogen Plant for Industry,Psa Nitrogen Generator and Nitrogen Making Machine manufacturers
2022-11-07
Solutions

Solutions to common faults of quality turnkey nitrogen generator system with high quality high req

Malaysia Psa Nitrogen Generator and Nitrogen Plant for Industry,Psa Nitrogen Generator and Nitrogen Making Machine manufacturers
2022-11-07
Solutions

Solutions to common faults of quality turnkey nitrogen generator system with high quality high req

Malaysia Psa Nitrogen Generator and Nitrogen Plant for Industry,Psa Nitrogen Generator and Nitrogen Making Machine manufacturers
2022-11-07

TEL:8613812770303
EMail:Andy@hjlgas.com
Address:Building 7, No.2318, East Taihu lake road,, Wuzhong District, Suzhou, China

HONGJINLI

Copyright © 2023 Suzhou Hong Jin Li Gas Equipment Co., Ltd.  All Rights Reserved. 苏ICP备15059125号-2  

HONG JI LI