Daily maintenance of energy saving nitrogen generators

Daily maintenance of energy saving nitrogen generators

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-07-20
  • Views:0

(Summary description)Daily maintenance of energy-saving nitrogen generators:
1. The air compressor should be maintained regularly, and the air filter, oil filter and oil should be replaced regularly according to the instructions.
2. The refrigerant pressure should be checked regularly for the refrigeration dryer and replenished in time. The dust of the heat sink should be purged with compressed air every day, and the filter element should be replaced regularly. The normal value is 8000H, depending on the specific situation and the pressure difference.

Daily maintenance of energy saving nitrogen generators

(Summary description)Daily maintenance of energy-saving nitrogen generators:
1. The air compressor should be maintained regularly, and the air filter, oil filter and oil should be replaced regularly according to the instructions.
2. The refrigerant pressure should be checked regularly for the refrigeration dryer and replenished in time. The dust of the heat sink should be purged with compressed air every day, and the filter element should be replaced regularly. The normal value is 8000H, depending on the specific situation and the pressure difference.

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-07-20
  • Views:0
Information

Daily maintenance of energy saving nitrogen generators:
1. The air compressor should be maintained regularly, and the air filter, oil filter and oil should be replaced regularly according to the instructions.
2. The refrigerant pressure should be checked regularly for the refrigeration dryer and replenished in time. The dust of the heat sink should be purged with compressed air every day, and the filter element should be replaced regularly. The normal value is 8000H, depending on the specific situation and the pressure difference.
3. The energy saving nitrogen generator needs to open the sewage outlet of the air storage tank once a day to drain the condensed water in the air.
4. Check the automatic drain every day to avoid blockage and loss of drainage. If it is blocked, open the manual valve slightly, close the self-draining valve, and then remove the automatic drain to disassemble and clean. When cleaning the auto drain, just use a soapy lather.

energy saving nitrogen generator
5. The energy saving nitrogen generator needs to regularly check the working pressure, purity and flow of the adsorption tower and make a record.
6. The activated carbon in the activated carbon filter is generally recommended to be replaced once a year.
7. If there is black smoke coming out of the muffler required by the energy saving nitrogen generator, it means that the molecular sieve is pulverized, and the machine should be stopped immediately for maintenance.
8. The nitrogen analyzer should be calibrated regularly, half a year is recommended.
9. The energy saving nitrogen generator needs to check the sensitivity of the pneumatic valve and the solenoid valve. The wear of the pneumatic valve affects the purity of nitrogen, which is a wearing part.
10. The safety valve should be calibrated by the corresponding institution every year.

Keyword:

Scan the QR code to read on your phone

Related News

What

What are the requirements for the installation site of the Psa Nitrogen Generator and Nitrogen Making Machine

The deployment of each equipment of the Psa Nitrogen Generator and Nitrogen Making Machine is connected and deployed in sequence according to the process flow. The user needs to provide the equipment installation plant size drawing and the position of the air inlet and the nitrogen outlet of the molded article according to the conditions of the user, and plan the deployment and connection diagram of the whole set of nitrogen generator equipment according to the actual site conditions.
2022-11-24
Features

Features of low purity PSA nitrogen generator and nitrogen plant

The low purity PSA nitrogen generator and nitrogen plant uses carbon molecular sieve as the adsorbent, and uses the difference in the adsorption amount of oxygen and nitrogen molecules in the compressed air in the carbon molecular sieve. Gas separation equipment for product nitrogen.
2022-11-11
The

The advantages of Food Packing and Storing Psa Nitrogen Gas Generator Nitrogen Plant for Food Industrial

The Food Packing and Storing Psa Nitrogen Gas Generator Nitrogen Plant for Food Industrial is a set of equipment that can extract nitrogen. The main application fields are: petrochemical, electronic industry scientific experiments and other fields. Turn on nitrogen.
2022-11-04
What

What should be paid attention to when the food packing and storing psa nitrogen gas generator nitrogen plant for food industrial is overhauled?

Food packing and storing psa nitrogen gas generator nitrogen plant for food industrial is a nitrogen generator designed and manufactured according to pressure swing adsorption technology.
2022-10-25

TEL:+8613812770303
EMail:Andy@hjlgas.com
Address:Building 7, No.2318, East Taihu lake road,, Wuzhong District, Suzhou, China

HONGJINLI

Copyright © 2021 Suzhou Hong Jin Li Gas Equipment Co., Ltd.  All Rights Reserved. 苏ICP备15059125号-2  Powered by www.300.cn

HONG JI LI