E-mail:Andy@hjlgas.com
The correct way to maintain the discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator
- Categories:Industry News
- Author:
- Origin:
- Time of issue:2022-06-30
- Views:0
(Summary description)Replace the activated carbon of the discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator (replace once every 12 months). The activated carbon link is a process of oil removal, which can reduce the oil content in the air and avoid the pollution and poisoning of the carbon molecular sieve of the nitrogen generator.
The correct way to maintain the discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator
(Summary description)Replace the activated carbon of the discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator (replace once every 12 months). The activated carbon link is a process of oil removal, which can reduce the oil content in the air and avoid the pollution and poisoning of the carbon molecular sieve of the nitrogen generator.
- Categories:Industry News
- Author:
- Origin:
- Time of issue:2022-06-30
- Views:0
1. Check the air treatment process, how is the cooling effect of the dryer, and replace the filter element of the pipe regularly (every six months) to make the air quality better.
2. Replace the activated carbon of the discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator (replace once every 12 months). The activated carbon link is a process of oil removal, which can reduce the oil content in the air and avoid the pollution and poisoning of the carbon molecular sieve of the nitrogen generator.
3. For the detection and calibration of nitrogen analyzer, the general life of nitrogen analyzer is 2-3 years, and it is recommended to replace it when the life expires to avoid misjudgment of the purity of discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator.
4. Check the solenoid valve and pneumatic valve. In order to ensure the normal operation of the equipment, it is recommended that the user keep a backup.
5. The carbon molecular sieve of the nitrogen generator (replaced once every 5-6 years) is analyzed and tested for nitrogen yield to ensure that the nitrogen yield meets the needs of customers. During maintenance, the carbon molecular sieve of discount ISO standard Chemical Nitrogen Plant and Nitrogen Generatorshould be added or replaced according to the customer's usage.
Scan the QR code to read on your phone
Related News


Precautions for choosing energy saving nitrogen generator manufacturers

Daily maintenance of energy saving nitrogen generators

Reasons for replacing carbon molecular sieves in quality energy saving nitrogen generators
Whatsapp:
TEL:+8613812770303
EMail:Andy@hjlgas.com
Address:Building 7, No.2318, East Taihu lake road,, Wuzhong District, Suzhou, China

Copyright © 2021 Suzhou Hong Jin Li Gas Equipment Co., Ltd. All Rights Reserved. 苏ICP备15059125号-2 Powered by www.300.cn