language
中国
韩国
韩国
韩国
韩国
韩国
Search
Submit
Cancel
NEWS
NEWS
>
>
>
The correct way to maintain the discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator

The correct way to maintain the discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-06-30
  • Views:0

(Summary description)Replace the activated carbon of the discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator (replace once every 12 months). The activated carbon link is a process of oil removal, which can reduce the oil content in the air and avoid the pollution and poisoning of the carbon molecular sieve of the nitrogen generator.

The correct way to maintain the discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator

(Summary description)Replace the activated carbon of the discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator (replace once every 12 months). The activated carbon link is a process of oil removal, which can reduce the oil content in the air and avoid the pollution and poisoning of the carbon molecular sieve of the nitrogen generator.

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-06-30
  • Views:0
Information

1. Check the air treatment process, how is the cooling effect of the dryer, and replace the filter element of the pipe regularly (every six months) to make the air quality better.
2. Replace the activated carbon of the discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator (replace once every 12 months). The activated carbon link is a process of oil removal, which can reduce the oil content in the air and avoid the pollution and poisoning of the carbon molecular sieve of the nitrogen generator.

discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator
3. For the detection and calibration of nitrogen analyzer, the general life of nitrogen analyzer is 2-3 years, and it is recommended to replace it when the life expires to avoid misjudgment of the purity of discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator.
4. Check the solenoid valve and pneumatic valve. In order to ensure the normal operation of the equipment, it is recommended that the user keep a backup.
5. The carbon molecular sieve of the nitrogen generator (replaced once every 5-6 years) is analyzed and tested for nitrogen yield to ensure that the nitrogen yield meets the needs of customers. During maintenance, the carbon molecular sieve of discount ISO standard Chemical Nitrogen Plant and Nitrogen Generatorshould be added or replaced according to the customer's usage.

Keyword:

Scan the QR code to read on your phone

Related News

Things

Things to know when choosing an energy saving nitrogen generator supplier

How to identify whether the energy saving nitrogen generator supplier is formal? The easiest way is to check whether the enterprise has the corresponding business license and production license and other qualification certificates.
2022-08-02
Precautions

Precautions for choosing energy saving nitrogen generator manufacturers

How to choose a satisfactory energy saving nitrogen generator manufacturer? It is completely unfamiliar to people who have not been exposed to this industry, and I don't know how to think about it. When choosing an energy saving nitrogen generator manufacturer, you need to pay attention to the following points:
2022-07-25
Daily

Daily maintenance of energy saving nitrogen generators

Daily maintenance of energy-saving nitrogen generators: 1. The air compressor should be maintained regularly, and the air filter, oil filter and oil should be replaced regularly according to the instructions. 2. The refrigerant pressure should be checked regularly for the refrigeration dryer and replenished in time. The dust of the heat sink should be purged with compressed air every day, and the filter element should be replaced regularly. The normal value is 8000H, depending on the specific situation and the pressure difference.
2022-07-20
Reasons

Reasons for replacing carbon molecular sieves in quality energy saving nitrogen generators

The replacement time of the carbon molecular sieve of the quality energy saving nitrogen generator mainly depends on the actual nitrogen purity of the outlet nitrogen. Any failure of the quality energy saving nitrogen generator will have a direct impact on nitrogen purity.
2022-07-15

TEL:+8613812770303
EMail:Andy@hjlgas.com
Address:Building 7, No.2318, East Taihu lake road,, Wuzhong District, Suzhou, China

HONGJINLI

Copyright © 2021 Suzhou Hong Jin Li Gas Equipment Co., Ltd.  All Rights Reserved. 苏ICP备15059125号-2  Powered by www.300.cn

HONG JI LI