Maintenance precautions for quality ISO standard Chemical Nitrogen Plant and Nitrogen Generator

Maintenance precautions for quality ISO standard Chemical Nitrogen Plant and Nitrogen Generator

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-06-27
  • Views:0

(Summary description)1. The normal supply and normal opening and closing of the power supply, gas source and temperature conditions required by the quality ISO standard Chemical Nitrogen Plant and Nitrogen Generator; especially the stability of the power supply voltage, reduce the damage to the controller and solenoid valve caused by the power supply problem.

Maintenance precautions for quality ISO standard Chemical Nitrogen Plant and Nitrogen Generator

(Summary description)1. The normal supply and normal opening and closing of the power supply, gas source and temperature conditions required by the quality ISO standard Chemical Nitrogen Plant and Nitrogen Generator; especially the stability of the power supply voltage, reduce the damage to the controller and solenoid valve caused by the power supply problem.

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-06-27
  • Views:0
Information

1. The normal supply and normal opening and closing of the power supply, gas source and temperature conditions required by the quality ISO standard Chemical Nitrogen Plant and Nitrogen Generator; especially the stability of the power supply voltage, reduce the damage to the controller and solenoid valve caused by the power supply problem.
2. Pay attention to the pressure of the air storage tank at any time, and keep the pressure of the air storage tank between 0.6 and 0.8MPa, not lower than the rated value.
3. Check the automatic drainer daily to avoid blockage and loss of drainage. If it is blocked, open the manual valve slightly, close the self-draining valve, and then remove the automatic drain to disassemble and clean. When cleaning the auto drain, just use a soapy lather.

quality ISO standard Chemical Nitrogen Plant and Nitrogen Generator
4. Check the three pressure gauges on the quality ISO standard Chemical Nitrogen Plant and Nitrogen Generator regularly, make a daily record of the pressure changes for equipment failure analysis, observe the flowmeter and nitrogen purity at any time, and keep the nitrogen purity of the outgoing gas.
5. Regularly check the refrigeration effect of the air dryer every week, so as to avoid the failure of the air dryer and the inflow of water into the nitrogen generator and the occurrence of carbon molecular sieve poisoning.
6. Operate and maintain the quality ISO standard Chemical Nitrogen Plant and Nitrogen Generator according to the requirements of the instrument use code, and check the sensitivity of the solenoid valve/pneumatic valve, the pressure range of the pressure regulating valve, the accuracy of the gas analyzer, the compression of the adsorption tower, and the exhaust condition of the muffler from time to time, the cleanliness of the inner tube of the flowmeter, etc.

Keyword:

Scan the QR code to read on your phone

Related News

Things

Things to know when choosing an energy saving nitrogen generator supplier

How to identify whether the energy saving nitrogen generator supplier is formal? The easiest way is to check whether the enterprise has the corresponding business license and production license and other qualification certificates.
2022-08-02
Precautions

Precautions for choosing energy saving nitrogen generator manufacturers

How to choose a satisfactory energy saving nitrogen generator manufacturer? It is completely unfamiliar to people who have not been exposed to this industry, and I don't know how to think about it. When choosing an energy saving nitrogen generator manufacturer, you need to pay attention to the following points:
2022-07-25
Daily

Daily maintenance of energy saving nitrogen generators

Daily maintenance of energy-saving nitrogen generators: 1. The air compressor should be maintained regularly, and the air filter, oil filter and oil should be replaced regularly according to the instructions. 2. The refrigerant pressure should be checked regularly for the refrigeration dryer and replenished in time. The dust of the heat sink should be purged with compressed air every day, and the filter element should be replaced regularly. The normal value is 8000H, depending on the specific situation and the pressure difference.
2022-07-20
Reasons

Reasons for replacing carbon molecular sieves in quality energy saving nitrogen generators

The replacement time of the carbon molecular sieve of the quality energy saving nitrogen generator mainly depends on the actual nitrogen purity of the outlet nitrogen. Any failure of the quality energy saving nitrogen generator will have a direct impact on nitrogen purity.