Key points of switching on and off the discount Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well

Key points of switching on and off the discount Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-06-11
  • Views:0

(Summary description)The discount Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well mainly adopts the pure physical separation method to extract nitrogen from the air. The nitrogen produced in this way has high purity, does not pollute the working environment, and does not corrode the instrument, thereby prolonging the service life of the instrument.

Key points of switching on and off the discount Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well

(Summary description)The discount Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well mainly adopts the pure physical separation method to extract nitrogen from the air. The nitrogen produced in this way has high purity, does not pollute the working environment, and does not corrode the instrument, thereby prolonging the service life of the instrument.

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-06-11
  • Views:0
Information

The discount Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well mainly adopts the pure physical separation method to extract nitrogen from the air. The nitrogen produced in this way has high purity, does not pollute the working environment, and does not corrode the instrument, thereby prolonging the service life of the instrument.
After using the discount Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well for a period of time, the user sometimes needs to suspend and restart the operation. There are some points that need to be paid attention to when the discount Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well is shut down and turned on.

discount Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well
Shutdown Tips:
1. Before shutting down the equipment, please confirm that the nitrogen application side is shut down and stop consuming nitrogen.
2. There is a power button on the front panel of the device, press the power button to turn off.
3. Pour out the waste liquid in the waste liquid collection bottle of the equipment.
4. The shutdown is completed.
Boot Tips:
1. Confirm that the power supply of the discount Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well is 220V, 50/60Hz. After the power supply is normal, press the power button to start.
2. The equipment starts to work, the air compressor starts, and the nitrogen pressure starts to rise.
3. After the nitrogen pressure reaches the set value (the default is 100psi), the nitrogen output can be turned on.
4. "NORMAL OPERATION" is displayed on the LCD touch screen of the equipment, and the discount Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well is ready for continuous supply of nitrogen.
5. The nitrogen supply is normal, and the back-end nitrogen application can be turned on.

Keyword:

Scan the QR code to read on your phone

Related News

How

How to choose a suitable cheap ISO standard Chemical Nitrogen Plant and Nitrogen Generator

The first thing to do is to determine where the cheap ISO standard Chemical Nitrogen Plant and Nitrogen Generator you want to buy will be used. Different products have different requirements for nitrogen purity. Some nitrogen generator manufacturers have many product specifications, and the prices of different specifications of equipment are also different. When many companies buy nitrogen generators, they hope that one piece of equipment can meet the applicable requirements of all their varieties, which is also the psychological need of every entrepreneur.
2022-07-03
The

The correct way to maintain the discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator

Replace the activated carbon of the discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator (replace once every 12 months). The activated carbon link is a process of oil removal, which can reduce the oil content in the air and avoid the pollution and poisoning of the carbon molecular sieve of the nitrogen generator.
2022-06-30
Maintenance

Maintenance precautions for quality ISO standard Chemical Nitrogen Plant and Nitrogen Generator

1. The normal supply and normal opening and closing of the power supply, gas source and temperature conditions required by the quality ISO standard Chemical Nitrogen Plant and Nitrogen Generator; especially the stability of the power supply voltage, reduce the damage to the controller and solenoid valve caused by the power supply problem.
2022-06-27
Maintenance

Maintenance precautions of customized ISO standard Chemical Nitrogen Plant and Nitrogen Generator

The safety matters that need to be paid attention to during the maintenance of customized ISO standard Chemical Nitrogen Plant and Nitrogen Generator: 1. Before maintenance, it is necessary to confirm that the customized ISO standard Chemical Nitrogen Plant and Nitrogen Generator is not in working state, and to ensure that the power supply has been cut off, and the deactivation sign is affixed before proceeding.
2022-06-24

TEL:+8613812770303
EMail:Andy@hjlgas.com
Address:Building 7, No.2318, East Taihu lake road,, Wuzhong District, Suzhou, China

HONGJINLI

Copyright © 2021 Suzhou Hong Jin Li Gas Equipment Co., Ltd.  All Rights Reserved. 苏ICP备15059125号-2  Powered by www.300.cn

HONG JI LI