language
中国
韩国
韩国
韩国
韩国
韩国
Search
Submit
Cancel
NEWS
NEWS
>
>
>
Maintenance method of customized Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well

Maintenance method of customized Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-06-05
  • Views:0

(Summary description)During the use of the customized Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well, users need to maintain it regularly, because regular maintenance can avoid some minor problems with the equipment. Let's talk about the correct maintenance method.

Maintenance method of customized Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well

(Summary description)During the use of the customized Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well, users need to maintain it regularly, because regular maintenance can avoid some minor problems with the equipment. Let's talk about the correct maintenance method.

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-06-05
  • Views:0
Information

During the use of the customized Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well, users need to maintain it regularly, because regular maintenance can avoid some minor problems with the equipment. Let's talk about the correct maintenance method.
1. The drying tube in the customized Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well should be replaced regularly. When 50% of the discolored silica gel in the drying tube is discolored, the internal packing should be replaced. Replacement method: Turn off the power, and bleed the system gas (pressure drop to zero). Unscrew the purification tube in the direction indicated by the arrow, unscrew the end cap of the purification tube, and replace the silica gel desiccant.
2. When replacing the desiccant, it should be noted that all the absorbent cotton is put into the tube to ensure that it has no effect on the sealing end face, so as to ensure that the end cap can be sealed after tightening.

customized Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well
3. When installing the customized Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well, screw it in the direction shown by the arrow. After starting the machine, use soap to check for leaks and ensure that it is sealed.
4. It is not allowed to wrap various sealing tapes on the thread surface of the drying pipe without authorization, otherwise the drying pipe will be cracked and cannot be sealed.
5. The electrolyte is consumed during the operation of the customized Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well, and distilled water should be replenished regularly according to the usage conditions to ensure that the liquid level is between the upper and lower limit scales.
6. The equipment does not consume KOH, but it is recommended to replace the electrolyte every six months. When replacing the electrolyte, first extract the waste lye in the nitrogen generator, add distilled water, start the instrument, let the system clean the electrolysis system for about 5-10 minutes, and then extract the Distilled water is added to the prepared new electrolytic lye.

Keyword:

Scan the QR code to read on your phone

Related News

How

How to choose a suitable cheap ISO standard Chemical Nitrogen Plant and Nitrogen Generator

The first thing to do is to determine where the cheap ISO standard Chemical Nitrogen Plant and Nitrogen Generator you want to buy will be used. Different products have different requirements for nitrogen purity. Some nitrogen generator manufacturers have many product specifications, and the prices of different specifications of equipment are also different. When many companies buy nitrogen generators, they hope that one piece of equipment can meet the applicable requirements of all their varieties, which is also the psychological need of every entrepreneur.
2022-07-03
The

The correct way to maintain the discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator

Replace the activated carbon of the discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator (replace once every 12 months). The activated carbon link is a process of oil removal, which can reduce the oil content in the air and avoid the pollution and poisoning of the carbon molecular sieve of the nitrogen generator.
2022-06-30
Maintenance

Maintenance precautions for quality ISO standard Chemical Nitrogen Plant and Nitrogen Generator

1. The normal supply and normal opening and closing of the power supply, gas source and temperature conditions required by the quality ISO standard Chemical Nitrogen Plant and Nitrogen Generator; especially the stability of the power supply voltage, reduce the damage to the controller and solenoid valve caused by the power supply problem.
2022-06-27
Maintenance

Maintenance precautions of customized ISO standard Chemical Nitrogen Plant and Nitrogen Generator

The safety matters that need to be paid attention to during the maintenance of customized ISO standard Chemical Nitrogen Plant and Nitrogen Generator: 1. Before maintenance, it is necessary to confirm that the customized ISO standard Chemical Nitrogen Plant and Nitrogen Generator is not in working state, and to ensure that the power supply has been cut off, and the deactivation sign is affixed before proceeding.
2022-06-24

TEL:+8613812770303
EMail:Andy@hjlgas.com
Address:Building 7, No.2318, East Taihu lake road,, Wuzhong District, Suzhou, China

HONGJINLI

Copyright © 2021 Suzhou Hong Jin Li Gas Equipment Co., Ltd.  All Rights Reserved. 苏ICP备15059125号-2  Powered by www.300.cn

HONG JI LI