What are the possible failures of Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well

What are the possible failures of Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-06-02
  • Views:0

(Summary description)Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well is an advanced gas separation technology. It uses high-quality imported carbon molecular sieve as adsorbent and adopts the principle of pressure swing adsorption at room temperature to separate air to produce high-purity nitrogen.

What are the possible failures of Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well

(Summary description)Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well is an advanced gas separation technology. It uses high-quality imported carbon molecular sieve as adsorbent and adopts the principle of pressure swing adsorption at room temperature to separate air to produce high-purity nitrogen.

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-06-02
  • Views:0
Information

Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well is an advanced gas separation technology. It uses high-quality imported carbon molecular sieve as adsorbent and adopts the principle of pressure swing adsorption at room temperature to separate air to produce high-purity nitrogen.
As a common instrument and equipment, Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well is unavoidable to have failures. It is very important to eliminate and check the problems in normal operation. So what are the possible failures of Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well?

Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well
1. There is a sound during the operation of the nitrogen generator:
Countermeasures: Use a wrench to properly adjust the tightness of the nut on the solenoid valve, not too tight; if not, you need to disassemble the solenoid valve to clean the interior (the noise is mainly due to impurities in the solenoid valve), if the cleaning does not work, it must be replaced new.
2. When the nitrogen generator is turned on, there is gas output:
Countermeasures: When the pressure rises just after starting the machine, you need to press the delay switch. Then continue to use it 10 minutes after the output pressure is released from the output end.
3. Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well cannot work when it is turned on, and the display panel has no display:
Countermeasures: firstly check whether the power supply is good, whether the plug is inserted properly, and then check whether the insurance is in good condition, and whether the cable plug-in of the instrument display board is properly inserted.
4. The nitrogen output from Skid Mounted Nitrogen Gas Generator for Pharmacutical, Oil Well is impure:
Countermeasures: Check whether the electrolyte concentration is too low, and whether the difference between the air pressure of the nitrogen generator and the air source pressure is too small.

Keyword:

Scan the QR code to read on your phone

Related News

How

How to choose a suitable cheap ISO standard Chemical Nitrogen Plant and Nitrogen Generator

The first thing to do is to determine where the cheap ISO standard Chemical Nitrogen Plant and Nitrogen Generator you want to buy will be used. Different products have different requirements for nitrogen purity. Some nitrogen generator manufacturers have many product specifications, and the prices of different specifications of equipment are also different. When many companies buy nitrogen generators, they hope that one piece of equipment can meet the applicable requirements of all their varieties, which is also the psychological need of every entrepreneur.
2022-07-03
The

The correct way to maintain the discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator

Replace the activated carbon of the discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator (replace once every 12 months). The activated carbon link is a process of oil removal, which can reduce the oil content in the air and avoid the pollution and poisoning of the carbon molecular sieve of the nitrogen generator.
2022-06-30
Maintenance

Maintenance precautions for quality ISO standard Chemical Nitrogen Plant and Nitrogen Generator

1. The normal supply and normal opening and closing of the power supply, gas source and temperature conditions required by the quality ISO standard Chemical Nitrogen Plant and Nitrogen Generator; especially the stability of the power supply voltage, reduce the damage to the controller and solenoid valve caused by the power supply problem.
2022-06-27
Maintenance

Maintenance precautions of customized ISO standard Chemical Nitrogen Plant and Nitrogen Generator

The safety matters that need to be paid attention to during the maintenance of customized ISO standard Chemical Nitrogen Plant and Nitrogen Generator: 1. Before maintenance, it is necessary to confirm that the customized ISO standard Chemical Nitrogen Plant and Nitrogen Generator is not in working state, and to ensure that the power supply has been cut off, and the deactivation sign is affixed before proceeding.
2022-06-24

TEL:+8613812770303
EMail:Andy@hjlgas.com
Address:Building 7, No.2318, East Taihu lake road,, Wuzhong District, Suzhou, China

HONGJINLI

Copyright © 2021 Suzhou Hong Jin Li Gas Equipment Co., Ltd.  All Rights Reserved. 苏ICP备15059125号-2  Powered by www.300.cn

HONG JI LI