Solutions to common faults of quality turnkey nitrogen generator system with high quality high req

Solutions to common faults of quality turnkey nitrogen generator system with high quality high req

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-05-12
  • Views:0

(Summary description)1. During the operation of quality turnkey nitrogen generator system with high quality high req, the number displayed on the meter head is large, and the pressure cannot reach the set value, which is caused by the leakage device. Carry out a comprehensive leak detection on the gas circuit, especially the drying room and the battery.

Solutions to common faults of quality turnkey nitrogen generator system with high quality high req

(Summary description)1. During the operation of quality turnkey nitrogen generator system with high quality high req, the number displayed on the meter head is large, and the pressure cannot reach the set value, which is caused by the leakage device. Carry out a comprehensive leak detection on the gas circuit, especially the drying room and the battery.

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-05-12
  • Views:0
Information

Solutions to common faults of quality turnkey nitrogen generator system with high quality high req
1. During the operation of quality turnkey nitrogen generator system with high quality high req, the number displayed on the meter head is large, and the pressure cannot reach the set value, which is caused by the leakage device. Carry out a comprehensive leak detection on the gas circuit, especially the drying room and the battery.
2. Check whether the battery is leaking and damaged
(1)Open the side panel of the instrument, observe the black rubber pad between the battery panels to see if there is any protruding deformation and water seepage, if so, replace the battery;
(2)Turn off the power after the nitrogen input pressure is 5KG, the battery water circuit should be static, if there are blisters continuously emerging, the battery is broken;

quality turnkey nitrogen generator system with high quality high req
3. There is a noise in the operation of quality turnkey nitrogen generator system with high quality high req, which is usually caused by the sound of the solenoid valve: use a 14 wrench to properly adjust the tightness of the nut on the solenoid valve, not too tight; if not, disassemble the solenoid valve to clean the interior (the main noise is It is because the solenoid valve is dirty with impurities), if it does not work after cleaning, it must be replaced with a new one.
4. Gas output when power on
When the pressure of quality turnkey nitrogen generator system with high quality high req just starts up, you need to press the red delay switch on the front, and then the output pressure is released, and it can be used after waiting for 10 minutes.

Keyword:

Scan the QR code to read on your phone

Related News

Precautions

Precautions for daily maintenance of low price turnkey nitrogen generator system with high quality high req

1. The normal supply and normal opening and closing of the power supply, gas source, and temperature conditions required by the low price turnkey nitrogen generator system with high quality high req; especially the stability of the power supply voltage, which reduces the damage to the controller and solenoid valve caused by the power supply problem.
2022-05-20
Precautions

Precautions for operation and maintenance of best turnkey nitrogen generator system with high quality high req

Precautions for monitoring during the operation of best turnkey nitrogen generator system with high quality high req: 1. Check the main parameters of the equipment every 1 hour. 2. Check the working condition of filter sewage every 2 hours. 3. Check the working condition of the air compressor for sewage discharge every 2 hours.
2022-05-17
Shutdown

Shutdown operation of China turnkey nitrogen generator system with high quality high req

Shutdown operation of China turnkey nitrogen generator system with high quality high req: 1. Close the nitrogen outlet valve. Close the air receiver outlet valve. 2. Turn off the nitrogen sampling flowmeter. 3. Press the [Stop] button. Power off the dryer. 4. Close the air compressor outlet valve. 5. Stop the air compressor.
2022-05-14
Solutions

Solutions to common faults of quality turnkey nitrogen generator system with high quality high req

1. During the operation of quality turnkey nitrogen generator system with high quality high req, the number displayed on the meter head is large, and the pressure cannot reach the set value, which is caused by the leakage device. Carry out a comprehensive leak detection on the gas circuit, especially the drying room and the battery.
2022-05-12

TEL:+8613812770303
EMail:Andy@hjlgas.com
Address:Building 7, No.2318, East Taihu lake road,, Wuzhong District, Suzhou, China

HONGJINLI

Copyright © 2021 Suzhou Hong Jin Li Gas Equipment Co., Ltd.  All Rights Reserved. 苏ICP备15059125号-2  Powered by www.300.cn

HONG JI LI