language
中国
韩国
韩国
韩国
韩国
韩国
Search
Submit
Cancel
NEWS
NEWS
>
>
>
Correct operating procedures for switching on and off of the Nitrogen Generator for food industry

Correct operating procedures for switching on and off of the Nitrogen Generator for food industry

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-04-15
  • Views:0

(Summary description)Many users have encountered many problems in the process of operating the Nitrogen Generator for food industry. The following are the correct operating procedures for switching on and off of the Nitrogen Generator for food industry.

Correct operating procedures for switching on and off of the Nitrogen Generator for food industry

(Summary description)Many users have encountered many problems in the process of operating the Nitrogen Generator for food industry. The following are the correct operating procedures for switching on and off of the Nitrogen Generator for food industry.

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-04-15
  • Views:0
Information

Many users have encountered many problems in the process of operating the Nitrogen Generator for food industry. The following are the correct operating procedures for switching on and off of the Nitrogen Generator for food industry.

Nitrogen Generator for food industry
Boot sequence:
1. First check the position of the system valve. The outlet valve of the air compressor is normally open, the valve door is closed, the water inlet and outlet valves of the booster are closed, and the intake valve of the nitrogen storage tank is closed.
2. Power up the system
3. Turn on the Nitrogen Generator for food industry, and after the meter shows a value, set the temperature value on the thermometer to 40°C and set the purity value on the purity table to 0.6.
4. Turn on the dryer and make it work for 1-2 minutes, and at the same time, check that the evaporation table cannot be 0.
5. Adjust the sampling flowmeter of the Nitrogen Generator for food industry to about 1.5.
Shutdown sequence:
1. Set the temperature on the temperature gauge of the Nitrogen Generator for food industry to 0°C. When the actual temperature is lower than 30°C, close the throttle of the nitrogen generator, make the intake pressure gauge 0, and turn off the air compressor.
2. Turn off the power of the dryer.
3. Turn off the power supply of the supercharger, then close the water inlet valve and the water return valve, and close the intake throttle of the nitrogen storage tank
4. Turn off the power of the Nitrogen Generator for food industry.

Keyword:

Scan the QR code to read on your phone

Related News

How

How to choose a suitable cheap ISO standard Chemical Nitrogen Plant and Nitrogen Generator

The first thing to do is to determine where the cheap ISO standard Chemical Nitrogen Plant and Nitrogen Generator you want to buy will be used. Different products have different requirements for nitrogen purity. Some nitrogen generator manufacturers have many product specifications, and the prices of different specifications of equipment are also different. When many companies buy nitrogen generators, they hope that one piece of equipment can meet the applicable requirements of all their varieties, which is also the psychological need of every entrepreneur.
2022-07-03
The

The correct way to maintain the discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator

Replace the activated carbon of the discount ISO standard Chemical Nitrogen Plant and Nitrogen Generator (replace once every 12 months). The activated carbon link is a process of oil removal, which can reduce the oil content in the air and avoid the pollution and poisoning of the carbon molecular sieve of the nitrogen generator.
2022-06-30
Maintenance

Maintenance precautions for quality ISO standard Chemical Nitrogen Plant and Nitrogen Generator

1. The normal supply and normal opening and closing of the power supply, gas source and temperature conditions required by the quality ISO standard Chemical Nitrogen Plant and Nitrogen Generator; especially the stability of the power supply voltage, reduce the damage to the controller and solenoid valve caused by the power supply problem.
2022-06-27
Maintenance

Maintenance precautions of customized ISO standard Chemical Nitrogen Plant and Nitrogen Generator

The safety matters that need to be paid attention to during the maintenance of customized ISO standard Chemical Nitrogen Plant and Nitrogen Generator: 1. Before maintenance, it is necessary to confirm that the customized ISO standard Chemical Nitrogen Plant and Nitrogen Generator is not in working state, and to ensure that the power supply has been cut off, and the deactivation sign is affixed before proceeding.
2022-06-24

TEL:+8613812770303
EMail:Andy@hjlgas.com
Address:Building 7, No.2318, East Taihu lake road,, Wuzhong District, Suzhou, China

HONGJINLI

Copyright © 2021 Suzhou Hong Jin Li Gas Equipment Co., Ltd.  All Rights Reserved. 苏ICP备15059125号-2  Powered by www.300.cn

HONG JI LI